Contact Us

Projects

Articulating Solar Array

We were able to help our client save over $40,000 on the design and construction of an articulating solar array.
Keep Reading
Pneumatic Air Cannon for Ballistic Testing

Ballistic Testing

Normally, we can test impacts using FEA. In this case, FEA wasn't feasible, so we built a test stand to test missile impacts on block walls.
Keep Reading

Check Valve Failure Analysis

We diagnosed the failure of a nozzle check valve in an Auxiliary Feedwater System at a power plant. In summary: great valve, wrong application.
Keep Reading

Condensate and Feedwater Upgrade

After an Extended Power Uprate (EPU), a power plant was having problems with Net Positive Suction Head (NPSH) on the Feedwater Pumps. They were worried about damaging the pump, but they also didn't want to replace it. We helped them without changing the pump.
Keep Reading

Custom Tool Design and Fabrication

Custom Tools A tool is a device or handheld implement that aids in accomplishing a task. When tasks become complex, the tools available at your local hardware store may not be the best choice. XCEED works closely with you and your maintenance staff to develop ideal, custom tools to solve your toughest problems, eliminate occupational hazards, […]
Keep Reading

Flood Penetration Qualification

We developed a testing plan to test seals and determine their water resistance. A test rig was designed which put a static head on the sample flood seals.
Keep Reading
Nuclear Regulatory Consulting

Fukushima FLEX Compliance Matrices

We have helped sites prepare for their TI-2515/191 inspections by using a tool we call the Compliance Matrix. Give us a call for more information.
Keep Reading
Construction

Missile Barrier Design Review

We worked with a nuclear plant to optimize a shear wall design. The optimized design reduced the amount of rebar by about 30%.
Keep Reading

Preventing Fatigue Failure

Pumps and compressors vibrate.  It’s a natural phenomena for anything that rotates or reciprocates, and it’s unavoidable. Normally, it’s not a problem. Until the vibrations hit resonance. When you have a pump or system operating at resonance, it can cause a fatigue failures. Recently, we found an example of this at a nuclear utility. They […]
Keep Reading

RCP Seal Leakoff

Using FEA and hand calculations, we were able to help a nuclear utility evaluate RCP Seal Leakoff pipes and components for high temperature and pressure.
Keep Reading
Steam Piping Integrity Evaluation

Steam Pipe Integrity Evaluation

Tornado generated missiles can wreak havoc, especially on a nuclear power plant. We helped one site design and optimize a protection system.
Keep Reading

Tank Impact Evaluation

We found that API-650 tanks are more robust than most expect. The water in this tank absorbed 30% of the energy of a truck going 93 mph!
Keep Reading
Missile Barrier Explicit FEA Results

Tornado Missile Barriers

A nuclear plant found that they needed to protect pipes from wind driven missiles. We designed a barrier system for them using 3D modeling and FEA.
Keep Reading

Transformer Foundation Design

We worked with a local utility to help design a foundation for a transformer. The design included the spill basin for transformer oil.
Keep Reading

Trenchless Pipe Rehabilitation

Eventually, most steel rusts. And most buried pipes are made from steel. So what do you do when your buried pipe gets rusty? What if the pipe leaked?
Keep Reading